Enforcement case

ENF-PMNT-26-021730

4506 BILES CT

Steps reached

  1. Complaint22 Sep 2026
  2. Inspection
  3. Violation23 Sep 2026
  4. Citation
  5. Hearing
  6. Lien
  7. Abatement
  8. Demolition
  9. Sale

Violations

CodeDescriptionFoundCompliedStatusCitation
E03Elect.23 Sep 2026Not recordedNew Violation
I03Door23 Sep 2026Not recordedNew Violation
T30Toilet
156.151-A
23 Sep 2026Not recordedNew Violation
R01Rental23 Sep 2026Not recordedNew Violation
X40Porch/balcony
156.053-B,K, 156.053-M
23 Sep 2026Not recordedNew Violation
I22Smoke23 Sep 2026Not recordedNew Violation

Steps

  1. Sep 22, 2026 · Complaint
    Interior
    Matched to this case by address and date.
  2. Sep 23, 2026 · Violation · Visit 1
    E03 - ELECT. RECEPTACLE OUTLET(S) [156.184-B] Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or receptacle with a ground fault circuit interrupter. Every bathroom shall contain at lest one receptacle. Any new or replaced bathroom receptacle outlet shall have ground fault circuit interrupter protection.
  3. Sep 23, 2026 · Violation · Visit 1
    I03 - DOOR (INTERIOR) [156.054-F] Every interior door shall fit reasonably well within its frame and shall be capable of being opened and closed by being properly and securely attached to jambs, headers or tracks as intended by the manufacturer of the attachment hardware.
  4. Sep 23, 2026 · Violation · Visit 1
    T30 - TOILET [156.151-A] Every dwelling unit shall contain its own bathtub or shower, lavatory, ...which shall be maintained in a sanitary, safe working condition. ...
  5. Sep 23, 2026 · Violation · Visit 1
    R01 - RENTAL REGISTRATION - RES. [119-LMCO] The failure to register a rental housing unit or apartment complex in accordance with LMCO 119.03 shall be classified as a civil offense with a penalty of up to $100 per rental housing unit or apartment complex. The owner or managing operator will be sent a ten day notice of violation with a warning of the failure to comply with the rental registry. Failure to comply at the end of ten days will result in a fine of up to $100 per rental housing unit or apartment complex. Thereafter, each day of such violation(s) shall constitute a separate offense.
  6. Sep 23, 2026 · Violation · Visit 1
    X40 - PORCH/BALCONY [156.053-B,K, 156.053-M] {B} All exterior surfaces,...porches...balconies,...shall be maintained in good condition. ... {K} Every exterior... porch and balcony, and all appurtenances attached thereto, shall be maintained structurally sound, in good repair, with proper anchorage and capable of supporting the imposed loads... {156.053-M] Every handrail and guard shall be firmly fastened... and shall be maintained in good condition. Every exterior flight of stairs having more than four risers, and every open portion of a stair, landing or balcony, which is more than 30 inches (762 mm) above the floor or grade below shall have guards. ...Guards shall not be less than 30 inches (762 mm) high above the floor of the landing, balcony or grade. Any alteration, modification, addition or replacement of a handrail or guard shall be in conformity with the applicable state building code requirements.
  7. Sep 23, 2026 · Violation · Visit 1
    I22 - SMOKE DETECTOR (INT. OF DWELLING) [156.203-B-1, 3, 4 - C-1,2,4,6] (Smoke Detector Interior of Dwelling Unit) {1} In all dwelling units, smoke detectors powered by a hard wire AC primary power source or a self-monitored, non-removal ten-year lithium battery shall be installed and maintained ... Single station detectors presently installed utilizing standard batteries may continue to be used as long as the units remain operational. ...{3} Smoke detectors shall be installed in accordance with applicable NFPA Standards and the manufacturer's recommendations. Detectors may be ceiling or wall mounted, provided that they shall be mounted at a minimum of four inches and a maximum of 12 inches from the ceiling {4} In a dwelling unit the detector shall be located in the corridor within the unit or interior area giving access to the rooms used for sleeping purposes. Where sleeping areas are separated and/or where a single smoke detector will not adequately service all sleeping areas, there shall be a smoke detector installed adjacent to each sleeping area... {C1} The owner of a dwelling shall be responsible for supplying and installing ... detectors ... {C2} The owner of a dwelling shall be responsible for maintenance and testing of detectors, in accordance with the manufacturer's instructions which are located in common areas...{C4} At every change of tenancy in all multi-family residential units and dormitories, it shall be the duty of the owner to test and ascertain that those detectors contained in the unit are in operable condition, and if not, the owner shall be responsible for placing them in operable condition. {C6} It shall be the responsibility of the property owner to install at least smoke detectors powered by a hardwire AC primary source or a self-monitored, non-removal ten year lithium battery before transfer of the property to a new party...

Hearings

No past hearing on file.

From Code Enforcement Board minutes and agendas.

Case record

CaseENF-PMNT-26-021730
OpenedSep 23, 2026
Furthest stepViolation found
Visits1
Hearings0

Follow this case— we will tell you when its status changes.