Enforcement case

ENF-PMNT-26-011775

1000 MAGAZINE ST

Steps reached

  1. Complaint4 Jun 2026
  2. Inspection
  3. Violation7 Jul 2026
  4. Citation
  5. Hearing
  6. Lien
  7. Abatement
  8. Demolition
  9. Sale

Violations

CodeDescriptionFoundCompliedStatusCitation
T05Bathtub/shower
156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D
7 Jul 2026Not recordedNew Violation
I13Interior7 Jul 2026Not recordedNew Violation
X07Door7 Jul 2026Not recordedNew Violation
Description not recorded7 Jul 2026Not recordedViolation Notice
T05Bathtub/shower
156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D
16 Jul 2026Not recordedPartial Compliance
I13Interior16 Jul 2026Not recordedNo Compliance
X07Door16 Jul 2026Not recordedNot Due
Description not recorded7 Aug 2026Not recordedClosed

Steps

  1. Jun 4, 2026 · Complaint
    Interior
    Matched to this case by address and date.
  2. Jul 6, 2026 · Complaint
    Interior
    Matched to this case by address and date.
  3. Jul 6, 2026 · Complaint
    Interior
    Matched to this case by address and date.
  4. Jul 6, 2026 · Complaint
    Interior
    Matched to this case by address and date.
  5. Jul 6, 2026 · Complaint
    Interior
    Matched to this case by address and date.
  6. Jul 6, 2026 · Complaint
    Interior
    Matched to this case by address and date.
  7. Jul 6, 2026 · Complaint
    Interior
    Matched to this case by address and date.
  8. Jul 7, 2026 · Violation · Visit 3
    T05 - BATHTUB/SHOWER [156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D] {A} Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. ... {B} At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. {C} Where private water closets, lavatories, and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each ten occupants... [156.155-A] Every...plumbing facility shall be properly connected to either the public sewer system or to an approved private sewage disposal system which shall meet the requirements of the Louisville/Jefferson County Department of Health... [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed... [156.054-C-2] ...The walls of every bathroom, to a height of 48 inches if there is a tub and 72 inches if there is a shower, shall be constructed of water-repellent material in that area adjacent to the tub or shower to prevent structural deterioration and any development of unsanitary conditions... [156.154-C] The water supply system shall ... provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks... {D] Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 120? F (49?C).
  9. Jul 7, 2026 · Violation · Visit 3
    I13 - INTERIOR SURFACE(S)/ CEILINGS/ WALLS/ FLOORS [156.054-C/156.054-C-1] {C} All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking, or abraded paint shall be repaired, removed, or covered. Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. {C-1} The owner must comply with federal and state statues and standards and local statutes and standards for the abatement of existing lead base paint and the application of lead base paint.
  10. Jul 7, 2026 · Violation · Visit 3
    X07 - DOOR (EXTERIOR) [156.053-O-1, 156.053-O-2] All exterior doors, door assemblies and hardware shall be maintained in good condition? [156.053-O-2] (Door lock provision for principle entry) Double cylinder dead bolts requiring a key operation on both sides are prohibited on required means of egress.
  11. Jul 7, 2026 · Violation · Visit 3
    (untitled)
  12. Jul 16, 2026 · Violation · Visit 4
    T05 - BATHTUB/SHOWER [156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D] {A} Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. ... {B} At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. {C} Where private water closets, lavatories, and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each ten occupants... [156.155-A] Every...plumbing facility shall be properly connected to either the public sewer system or to an approved private sewage disposal system which shall meet the requirements of the Louisville/Jefferson County Department of Health... [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed... [156.054-C-2] ...The walls of every bathroom, to a height of 48 inches if there is a tub and 72 inches if there is a shower, shall be constructed of water-repellent material in that area adjacent to the tub or shower to prevent structural deterioration and any development of unsanitary conditions... [156.154-C] The water supply system shall ... provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks... {D] Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 120? F (49?C).
  13. Jul 16, 2026 · Violation · Visit 4
    I13 - INTERIOR SURFACE(S)/ CEILINGS/ WALLS/ FLOORS [156.054-C/156.054-C-1] {C} All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking, or abraded paint shall be repaired, removed, or covered. Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. {C-1} The owner must comply with federal and state statues and standards and local statutes and standards for the abatement of existing lead base paint and the application of lead base paint.
  14. Jul 16, 2026 · Violation · Visit 4
    X07 - DOOR (EXTERIOR) [156.053-O-1, 156.053-O-2] All exterior doors, door assemblies and hardware shall be maintained in good condition? [156.053-O-2] (Door lock provision for principle entry) Double cylinder dead bolts requiring a key operation on both sides are prohibited on required means of egress.
  15. Aug 7, 2026 · Violation · Visit 5
    (untitled)

Hearings

No past hearing on file.

From Code Enforcement Board minutes and agendas.

Case record

CaseENF-PMNT-26-011775