Enforcement case

ENF-PMNT-26-005484

4133 FLINTLOCK DR 26

Steps reached

  1. Complaint24 Aug 2026
  2. Inspection
  3. Violation19 Aug 2026
  4. Citation
  5. Hearing
  6. Lien
  7. Abatement
  8. Demolition
  9. Sale

Violations

CodeDescriptionFoundCompliedStatusCitation
E03Elect.19 Aug 2026Not recordedNew Violation
I03Door19 Aug 2026Not recordedNew Violation
T05Bathtub/shower
156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D
19 Aug 2026Not recordedNew Violation
T22Lavatory19 Aug 2026Not recordedNew Violation
I13Interior19 Aug 2026Not recordedNew Violation
M23Furnace
156.182-A,B,C,D,F
19 Aug 2026Not recordedNew Violation

Steps

  1. Aug 19, 2026 · Violation · Visit 2
    E03 - ELECT. RECEPTACLE OUTLET(S) [156.184-B] Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or receptacle with a ground fault circuit interrupter. Every bathroom shall contain at lest one receptacle. Any new or replaced bathroom receptacle outlet shall have ground fault circuit interrupter protection.
  2. Aug 19, 2026 · Violation · Visit 2
    I03 - DOOR (INTERIOR) [156.054-F] Every interior door shall fit reasonably well within its frame and shall be capable of being opened and closed by being properly and securely attached to jambs, headers or tracks as intended by the manufacturer of the attachment hardware.
  3. Aug 19, 2026 · Violation · Visit 2
    T05 - BATHTUB/SHOWER [156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D] {A} Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. ... {B} At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. {C} Where private water closets, lavatories, and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each ten occupants... [156.155-A] Every...plumbing facility shall be properly connected to either the public sewer system or to an approved private sewage disposal system which shall meet the requirements of the Louisville/Jefferson County Department of Health... [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed... [156.054-C-2] ...The walls of every bathroom, to a height of 48 inches if there is a tub and 72 inches if there is a shower, shall be constructed of water-repellent material in that area adjacent to the tub or shower to prevent structural deterioration and any development of unsanitary conditions... [156.154-C] The water supply system shall ... provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks... {D] Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 120? F (49?C).
  4. Aug 19, 2026 · Violation · Visit 2
    T22 - LAVATORY BASIN [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. All plumbing fixtures shall be maintained in a safe, sanitary and functional condition.
  5. Aug 19, 2026 · Violation · Visit 2
    I13 - INTERIOR SURFACE(S)/ CEILINGS/ WALLS/ FLOORS [156.054-C/156.054-C-1] {C} All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking, or abraded paint shall be repaired, removed, or covered. Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. {C-1} The owner must comply with federal and state statues and standards and local statutes and standards for the abatement of existing lead base paint and the application of lead base paint.
  6. Aug 19, 2026 · Violation · Visit 2
    M23 - FURNACE [156.182-A,B,C,D,F] ? {A] fireplaces, solid fuel-burning appliances,...shall be properly installed and maintained in a safe working condition, and shall be capable of performing the intended function? {B] All fuel-burning equipment ... shall be connected to an approved chimney or vent ... {C} All required clearances to combustible materials shall be maintained... {D} All safety controls for fuel-burning equipment shall be maintained in effective operation... {F} Energy conservation devices. Devices intended to reduce fuel consumption by attachment to a fuel burning appliance, to the fuel supply line thereto, or to the vent outlet or vent piping therefrom, shall not be installed unless labeled for such purpose and the installation is specifically approved.
  7. Aug 24, 2026 · Complaint
    Interior
    Matched to this case by address and date.

Hearings

No past hearing on file.

From Code Enforcement Board minutes and agendas.

Case record

CaseENF-PMNT-26-005484
OpenedAug 19, 2026
Furthest stepViolation found
Visits2
Hearings0

Follow this case— we will tell you when its status changes.

Location

Location of enforcement case ENF-PMNT-26-005484. Map data © OpenStreetMap contributors

The map is a shortcut. Everything on it is also on this page as text.

Records