Enforcement case
ENF-PMNT-25-014454
PMNT · Opened Jun 5, 2026
Steps reached
- Complaint
- Inspection
- Violation6 Jul 2026
- Citation$1,400.00
- Hearing5 Jun 2026
- Lien24 Aug 2026
- Abatement
- Demolition
- Sale
Violations
| Code | Description | Found | Complied | Status | Citation |
|---|---|---|---|---|---|
| 07A | Rodents/ | 6 Jul 2026 | Not recorded | No Entry | |
| E02 | Elect. | 6 Jul 2026 | Not recorded | No Entry | |
| E03 | Elect. | 6 Jul 2026 | Not recorded | No Entry | |
| I11 | Floor | 6 Jul 2026 | Not recorded | No Entry | |
| K10 | Kitchen | 6 Jul 2026 | Not recorded | No Entry | |
| M99 | Air | 6 Jul 2026 | Not recorded | No Entry | |
| T05 | Bathtub/shower 156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D | 6 Jul 2026 | Not recorded | No Entry | |
| T22 | Lavatory | 6 Jul 2026 | Not recorded | No Entry | |
| T30 | Toilet 156.151-A | 6 Jul 2026 | Not recorded | No Entry | |
| I13 | Interior | 6 Jul 2026 | Not recorded | No Entry | |
| I22 | Smoke | 6 Jul 2026 | Not recorded | No Entry | |
| X07 | Door | 6 Jul 2026 | Not recorded | No Entry | |
| E02 | Elect. | 9 Jul 2026 | Not recorded | No Compliance | |
| E03 | Elect. | 9 Jul 2026 | Not recorded | No Compliance | |
| I11 | Floor | 9 Jul 2026 | Not recorded | Partial Compliance | |
| K10 | Kitchen | 9 Jul 2026 | Not recorded | No Entry | |
| M99 | Air | 9 Jul 2026 | Not recorded | Partial Compliance | |
| T05 | Bathtub/shower 156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D | 9 Jul 2026 | Not recorded | Partial Compliance | |
| T22 | Lavatory | 9 Jul 2026 | Not recorded | No Entry | |
| I13 | Interior | 9 Jul 2026 | Not recorded | No Compliance | |
| X07 | Door | 9 Jul 2026 | Not recorded | Partial Compliance | |
| 02A | Cleaning 156.052-D/156.055-A/156.052-K | 18 Aug 2026 | Not recorded | New Violation | |
| E02 | Elect. | 18 Aug 2026 | Not recorded | No Entry | |
| E03 | Elect. | 18 Aug 2026 | Not recorded | No Entry | |
| I11 | Floor | 18 Aug 2026 | Not recorded | No Entry | |
| K10 | Kitchen | 18 Aug 2026 | Not recorded | No Entry | |
| M99 | Air | 18 Aug 2026 | Not recorded | No Entry | |
| T05 | Bathtub/shower 156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D | 18 Aug 2026 | Not recorded | No Entry | |
| T22 | Lavatory | 18 Aug 2026 | Not recorded | No Entry | |
| I13 | Interior | 18 Aug 2026 | Not recorded | No Entry | |
| X07 | Door | 18 Aug 2026 | Not recorded | No Entry | |
| 02A | Cleaning 156.052-D/156.055-A/156.052-K | 24 Aug 2026 | Not recorded | Partial Compliance | 1,400.00 |
| E02 | Elect. | 24 Aug 2026 | Not recorded | No Compliance | 1,400.00 |
| E03 | Elect. | 24 Aug 2026 | Not recorded | No Compliance | 1,400.00 |
| I11 | Floor | 24 Aug 2026 | Not recorded | No Compliance | 1,400.00 |
| K10 | Kitchen | 24 Aug 2026 | Not recorded | No Compliance | 1,400.00 |
| M99 | Air | 24 Aug 2026 | Not recorded | No Compliance | 1,400.00 |
| T05 | Bathtub/shower 156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D | 24 Aug 2026 | Not recorded | No Compliance | 1,400.00 |
| T22 | Lavatory | 24 Aug 2026 | Not recorded | No Compliance | 1,400.00 |
| I13 | Interior | 24 Aug 2026 | Not recorded | No Compliance | 1,400.00 |
| X07 | Door | 24 Aug 2026 | Not recorded | No Compliance | 1,400.00 |
Steps
- Jun 5, 2026 · Board hearing · Visit 8On the Board's docket.
- Jul 6, 2026 · Violation · Visit 1107A - RODENTS/ MOSQUITO BAIT TRACKING [156.052-F] All structures and exterior property shall be kept free from rodent harborage and infestation. Where rodents are found, they shall be promptly exterminated by approved processes,...
- Jul 6, 2026 · Violation · Visit 11E02 - ELECT. LIGHTING FIXTURE [156.184-C] Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain at least one electric lighting fixture.
- Jul 6, 2026 · Violation · Visit 11E03 - ELECT. RECEPTACLE OUTLET(S) [156.184-B] Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or receptacle with a ground fault circuit interrupter. Every bathroom shall contain at lest one receptacle. Any new or replaced bathroom receptacle outlet shall have ground fault circuit interrupter protection.
- Jul 6, 2026 · Violation · Visit 11I11 - FLOOR (INTERIOR) [156.054-C] All interior surfaces...shall be maintained in good, clean and sanitary condition. ...Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected.
- Jul 6, 2026 · Violation · Visit 11K10 - KITCHEN SINK [156.151-A] Every dwelling unit shall contain its own ... kitchen sink which shall be maintained in a sanitary, safe working condition. ...
- Jul 6, 2026 · Violation · Visit 11M99 - AIR CONDITIONING UNITS [156.051-B-7] Supplied Fixtures and Equipment: The owner or occupant of a structure or part thereof shall keep all equipment and fixtures therein clean and sanitary, and shall be responsible for the exercise of reasonable care in their proper use and operation. The owner shall maintain the supplied equipment and fixtures in good and proper operating condition. All air conditioning units must be maintained in a safe and operable condition.
- Jul 6, 2026 · Violation · Visit 11T05 - BATHTUB/SHOWER [156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D] {A} Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. ... {B} At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. {C} Where private water closets, lavatories, and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each ten occupants... [156.155-A] Every...plumbing facility shall be properly connected to either the public sewer system or to an approved private sewage disposal system which shall meet the requirements of the Louisville/Jefferson County Department of Health... [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed... [156.054-C-2] ...The walls of every bathroom, to a height of 48 inches if there is a tub and 72 inches if there is a shower, shall be constructed of water-repellent material in that area adjacent to the tub or shower to prevent structural deterioration and any development of unsanitary conditions... [156.154-C] The water supply system shall ... provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks... {D] Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 120? F (49?C).
- Jul 6, 2026 · Violation · Visit 11T22 - LAVATORY BASIN [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. All plumbing fixtures shall be maintained in a safe, sanitary and functional condition.
- Jul 6, 2026 · Violation · Visit 11T30 - TOILET [156.151-A] Every dwelling unit shall contain its own bathtub or shower, lavatory, ...which shall be maintained in a sanitary, safe working condition. ...
- Jul 6, 2026 · Violation · Visit 11I13 - INTERIOR SURFACE(S)/ CEILINGS/ WALLS/ FLOORS [156.054-C/156.054-C-1] {C} All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking, or abraded paint shall be repaired, removed, or covered. Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. {C-1} The owner must comply with federal and state statues and standards and local statutes and standards for the abatement of existing lead base paint and the application of lead base paint.
- Jul 6, 2026 · Violation · Visit 11I22 - SMOKE DETECTOR (INT. OF DWELLING) [156.203-B-1, 3, 4 - C-1,2,4,6] (Smoke Detector Interior of Dwelling Unit) {1} In all dwelling units, smoke detectors powered by a hard wire AC primary power source or a self-monitored, non-removal ten-year lithium battery shall be installed and maintained ... Single station detectors presently installed utilizing standard batteries may continue to be used as long as the units remain operational. ...{3} Smoke detectors shall be installed in accordance with applicable NFPA Standards and the manufacturer's recommendations. Detectors may be ceiling or wall mounted, provided that they shall be mounted at a minimum of four inches and a maximum of 12 inches from the ceiling {4} In a dwelling unit the detector shall be located in the corridor within the unit or interior area giving access to the rooms used for sleeping purposes. Where sleeping areas are separated and/or where a single smoke detector will not adequately service all sleeping areas, there shall be a smoke detector installed adjacent to each sleeping area... {C1} The owner of a dwelling shall be responsible for supplying and installing ... detectors ... {C2} The owner of a dwelling shall be responsible for maintenance and testing of detectors, in accordance with the manufacturer's instructions which are located in common areas...{C4} At every change of tenancy in all multi-family residential units and dormitories, it shall be the duty of the owner to test and ascertain that those detectors contained in the unit are in operable condition, and if not, the owner shall be responsible for placing them in operable condition. {C6} It shall be the responsibility of the property owner to install at least smoke detectors powered by a hardwire AC primary source or a self-monitored, non-removal ten year lithium battery before transfer of the property to a new party...
- Jul 6, 2026 · Violation · Visit 11X07 - DOOR (EXTERIOR) [156.053-O-1, 156.053-O-2] All exterior doors, door assemblies and hardware shall be maintained in good condition? [156.053-O-2] (Door lock provision for principle entry) Double cylinder dead bolts requiring a key operation on both sides are prohibited on required means of egress.
- Jul 9, 2026 · Violation · Visit 12E02 - ELECT. LIGHTING FIXTURE [156.184-C] Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain at least one electric lighting fixture.
- Jul 9, 2026 · Violation · Visit 12E03 - ELECT. RECEPTACLE OUTLET(S) [156.184-B] Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or receptacle with a ground fault circuit interrupter. Every bathroom shall contain at lest one receptacle. Any new or replaced bathroom receptacle outlet shall have ground fault circuit interrupter protection.
- Jul 9, 2026 · Violation · Visit 12I11 - FLOOR (INTERIOR) [156.054-C] All interior surfaces...shall be maintained in good, clean and sanitary condition. ...Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected.
- Jul 9, 2026 · Violation · Visit 12K10 - KITCHEN SINK [156.151-A] Every dwelling unit shall contain its own ... kitchen sink which shall be maintained in a sanitary, safe working condition. ...
- Jul 9, 2026 · Violation · Visit 12M99 - AIR CONDITIONING UNITS [156.051-B-7] Supplied Fixtures and Equipment: The owner or occupant of a structure or part thereof shall keep all equipment and fixtures therein clean and sanitary, and shall be responsible for the exercise of reasonable care in their proper use and operation. The owner shall maintain the supplied equipment and fixtures in good and proper operating condition. All air conditioning units must be maintained in a safe and operable condition.
- Jul 9, 2026 · Violation · Visit 12T05 - BATHTUB/SHOWER [156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D] {A} Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. ... {B} At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. {C} Where private water closets, lavatories, and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each ten occupants... [156.155-A] Every...plumbing facility shall be properly connected to either the public sewer system or to an approved private sewage disposal system which shall meet the requirements of the Louisville/Jefferson County Department of Health... [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed... [156.054-C-2] ...The walls of every bathroom, to a height of 48 inches if there is a tub and 72 inches if there is a shower, shall be constructed of water-repellent material in that area adjacent to the tub or shower to prevent structural deterioration and any development of unsanitary conditions... [156.154-C] The water supply system shall ... provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks... {D] Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 120? F (49?C).
- Jul 9, 2026 · Violation · Visit 12T22 - LAVATORY BASIN [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. All plumbing fixtures shall be maintained in a safe, sanitary and functional condition.
- Jul 9, 2026 · Violation · Visit 12I13 - INTERIOR SURFACE(S)/ CEILINGS/ WALLS/ FLOORS [156.054-C/156.054-C-1] {C} All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking, or abraded paint shall be repaired, removed, or covered. Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. {C-1} The owner must comply with federal and state statues and standards and local statutes and standards for the abatement of existing lead base paint and the application of lead base paint.
- Jul 9, 2026 · Violation · Visit 12X07 - DOOR (EXTERIOR) [156.053-O-1, 156.053-O-2] All exterior doors, door assemblies and hardware shall be maintained in good condition? [156.053-O-2] (Door lock provision for principle entry) Double cylinder dead bolts requiring a key operation on both sides are prohibited on required means of egress.
- Aug 18, 2026 · Violation · Visit 1302A - CLEANING [156.052-D/156.055-A/156.052-K] {156.052-D}.....All premises shall be maintained free from weeds or plant growth in excess of ten inches. All noxious weeds shall be prohibited. Any land of more than three acres that abut another parcel which contains a dwelling or commercial building thereon shall be weed free at least 50 feet from the property line or 200 feet from an occupied structure, or {156.055-A} All exterior property and premises, and the interior of every structure, shall be free from any accumulation of rubbish or garbage, or {156.52-I} No person shall willfully or wantonly damage, mutilate or deface any exterior surface by placing thereon any marking, carving or graffiti. It shall be the responsibility of the owner to restore said surface.
- Aug 18, 2026 · Violation · Visit 13E02 - ELECT. LIGHTING FIXTURE [156.184-C] Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain at least one electric lighting fixture.
- Aug 18, 2026 · Violation · Visit 13E03 - ELECT. RECEPTACLE OUTLET(S) [156.184-B] Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or receptacle with a ground fault circuit interrupter. Every bathroom shall contain at lest one receptacle. Any new or replaced bathroom receptacle outlet shall have ground fault circuit interrupter protection.
- Aug 18, 2026 · Violation · Visit 13I11 - FLOOR (INTERIOR) [156.054-C] All interior surfaces...shall be maintained in good, clean and sanitary condition. ...Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected.
- Aug 18, 2026 · Violation · Visit 13K10 - KITCHEN SINK [156.151-A] Every dwelling unit shall contain its own ... kitchen sink which shall be maintained in a sanitary, safe working condition. ...
- Aug 18, 2026 · Violation · Visit 13M99 - AIR CONDITIONING UNITS [156.051-B-7] Supplied Fixtures and Equipment: The owner or occupant of a structure or part thereof shall keep all equipment and fixtures therein clean and sanitary, and shall be responsible for the exercise of reasonable care in their proper use and operation. The owner shall maintain the supplied equipment and fixtures in good and proper operating condition. All air conditioning units must be maintained in a safe and operable condition.
- Aug 18, 2026 · Violation · Visit 13T05 - BATHTUB/SHOWER [156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D] {A} Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. ... {B} At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. {C} Where private water closets, lavatories, and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each ten occupants... [156.155-A] Every...plumbing facility shall be properly connected to either the public sewer system or to an approved private sewage disposal system which shall meet the requirements of the Louisville/Jefferson County Department of Health... [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed... [156.054-C-2] ...The walls of every bathroom, to a height of 48 inches if there is a tub and 72 inches if there is a shower, shall be constructed of water-repellent material in that area adjacent to the tub or shower to prevent structural deterioration and any development of unsanitary conditions... [156.154-C] The water supply system shall ... provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks... {D] Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 120? F (49?C).
- Aug 18, 2026 · Violation · Visit 13T22 - LAVATORY BASIN [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. All plumbing fixtures shall be maintained in a safe, sanitary and functional condition.
- Aug 18, 2026 · Violation · Visit 13I13 - INTERIOR SURFACE(S)/ CEILINGS/ WALLS/ FLOORS [156.054-C/156.054-C-1] {C} All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking, or abraded paint shall be repaired, removed, or covered. Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. {C-1} The owner must comply with federal and state statues and standards and local statutes and standards for the abatement of existing lead base paint and the application of lead base paint.
- Aug 18, 2026 · Violation · Visit 13X07 - DOOR (EXTERIOR) [156.053-O-1, 156.053-O-2] All exterior doors, door assemblies and hardware shall be maintained in good condition? [156.053-O-2] (Door lock provision for principle entry) Double cylinder dead bolts requiring a key operation on both sides are prohibited on required means of egress.
- Aug 24, 2026 · Violation · Visit 1402A - CLEANING [156.052-D/156.055-A/156.052-K] {156.052-D}.....All premises shall be maintained free from weeds or plant growth in excess of ten inches. All noxious weeds shall be prohibited. Any land of more than three acres that abut another parcel which contains a dwelling or commercial building thereon shall be weed free at least 50 feet from the property line or 200 feet from an occupied structure, or {156.055-A} All exterior property and premises, and the interior of every structure, shall be free from any accumulation of rubbish or garbage, or {156.52-I} No person shall willfully or wantonly damage, mutilate or deface any exterior surface by placing thereon any marking, carving or graffiti. It shall be the responsibility of the owner to restore said surface.
- Aug 24, 2026 · Violation · Visit 14E02 - ELECT. LIGHTING FIXTURE [156.184-C] Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain at least one electric lighting fixture.
- Aug 24, 2026 · Violation · Visit 14E03 - ELECT. RECEPTACLE OUTLET(S) [156.184-B] Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or receptacle with a ground fault circuit interrupter. Every bathroom shall contain at lest one receptacle. Any new or replaced bathroom receptacle outlet shall have ground fault circuit interrupter protection.
- Aug 24, 2026 · Violation · Visit 14I11 - FLOOR (INTERIOR) [156.054-C] All interior surfaces...shall be maintained in good, clean and sanitary condition. ...Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected.
- Aug 24, 2026 · Violation · Visit 14K10 - KITCHEN SINK [156.151-A] Every dwelling unit shall contain its own ... kitchen sink which shall be maintained in a sanitary, safe working condition. ...
- Aug 24, 2026 · Violation · Visit 14M99 - AIR CONDITIONING UNITS [156.051-B-7] Supplied Fixtures and Equipment: The owner or occupant of a structure or part thereof shall keep all equipment and fixtures therein clean and sanitary, and shall be responsible for the exercise of reasonable care in their proper use and operation. The owner shall maintain the supplied equipment and fixtures in good and proper operating condition. All air conditioning units must be maintained in a safe and operable condition.
- Aug 24, 2026 · Violation · Visit 14T05 - BATHTUB/SHOWER [156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D] {A} Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. ... {B} At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. {C} Where private water closets, lavatories, and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each ten occupants... [156.155-A] Every...plumbing facility shall be properly connected to either the public sewer system or to an approved private sewage disposal system which shall meet the requirements of the Louisville/Jefferson County Department of Health... [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed... [156.054-C-2] ...The walls of every bathroom, to a height of 48 inches if there is a tub and 72 inches if there is a shower, shall be constructed of water-repellent material in that area adjacent to the tub or shower to prevent structural deterioration and any development of unsanitary conditions... [156.154-C] The water supply system shall ... provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks... {D] Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 120? F (49?C).
- Aug 24, 2026 · Violation · Visit 14T22 - LAVATORY BASIN [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. All plumbing fixtures shall be maintained in a safe, sanitary and functional condition.
- Aug 24, 2026 · Violation · Visit 14I13 - INTERIOR SURFACE(S)/ CEILINGS/ WALLS/ FLOORS [156.054-C/156.054-C-1] {C} All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking, or abraded paint shall be repaired, removed, or covered. Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. {C-1} The owner must comply with federal and state statues and standards and local statutes and standards for the abatement of existing lead base paint and the application of lead base paint.
- Aug 24, 2026 · Violation · Visit 14X07 - DOOR (EXTERIOR) [156.053-O-1, 156.053-O-2] All exterior doors, door assemblies and hardware shall be maintained in good condition? [156.053-O-2] (Door lock provision for principle entry) Double cylinder dead bolts requiring a key operation on both sides are prohibited on required means of egress.
- Aug 24, 2026 · LienLien notification — Final By Citation
Hearings
- Jun 5, 2026 · Code Enforcement BoardOn the Board's docket.
From Code Enforcement Board minutes and agendas.
Case record
Follow this case— we will tell you when its status changes.
Location
The map is a shortcut. Everything on it is also on this page as text.
Records
- 07A - RODENTS/ MOSQUITO BAIT TRACKING [156.052-F] All structures and exterior property shall be kept free from rodent harborage and infestation. Where rodents are found, they shall be promptly exterminated by approved processes,... · Violation · ENF-PMNT-25-014454
- E02 - ELECT. LIGHTING FIXTURE [156.184-C] Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain at least one electric lighting fixture. · Violation · ENF-PMNT-25-014454
- E03 - ELECT. RECEPTACLE OUTLET(S) [156.184-B] Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or receptacle with a ground fault circuit interrupter. Every bathroom shall contain at lest one receptacle. Any new or replaced bathroom receptacle outlet shall have ground fault circuit interrupter protection. · Violation · ENF-PMNT-25-014454
- I11 - FLOOR (INTERIOR) [156.054-C] All interior surfaces...shall be maintained in good, clean and sanitary condition. ...Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. · Violation · ENF-PMNT-25-014454
- K10 - KITCHEN SINK [156.151-A] Every dwelling unit shall contain its own ... kitchen sink which shall be maintained in a sanitary, safe working condition. ... · Violation · ENF-PMNT-25-014454
- M99 - AIR CONDITIONING UNITS [156.051-B-7] Supplied Fixtures and Equipment: The owner or occupant of a structure or part thereof shall keep all equipment and fixtures therein clean and sanitary, and shall be responsible for the exercise of reasonable care in their proper use and operation. The owner shall maintain the supplied equipment and fixtures in good and proper operating condition. All air conditioning units must be maintained in a safe and operable condition. · Violation · ENF-PMNT-25-014454
- T05 - BATHTUB/SHOWER [156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D] {A} Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. ... {B} At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. {C} Where private water closets, lavatories, and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each ten occupants... [156.155-A] Every...plumbing facility shall be properly connected to either the public sewer system or to an approved private sewage disposal system which shall meet the requirements of the Louisville/Jefferson County Department of Health... [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed... [156.054-C-2] ...The walls of every bathroom, to a height of 48 inches if there is a tub and 72 inches if there is a shower, shall be constructed of water-repellent material in that area adjacent to the tub or shower to prevent structural deterioration and any development of unsanitary conditions... [156.154-C] The water supply system shall ... provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks... {D] Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 120? F (49?C). · Violation · ENF-PMNT-25-014454
- T22 - LAVATORY BASIN [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. All plumbing fixtures shall be maintained in a safe, sanitary and functional condition. · Violation · ENF-PMNT-25-014454
- T30 - TOILET [156.151-A] Every dwelling unit shall contain its own bathtub or shower, lavatory, ...which shall be maintained in a sanitary, safe working condition. ... · Violation · ENF-PMNT-25-014454
- I13 - INTERIOR SURFACE(S)/ CEILINGS/ WALLS/ FLOORS [156.054-C/156.054-C-1] {C} All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking, or abraded paint shall be repaired, removed, or covered. Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. {C-1} The owner must comply with federal and state statues and standards and local statutes and standards for the abatement of existing lead base paint and the application of lead base paint. · Violation · ENF-PMNT-25-014454
- I22 - SMOKE DETECTOR (INT. OF DWELLING) [156.203-B-1, 3, 4 - C-1,2,4,6] (Smoke Detector Interior of Dwelling Unit) {1} In all dwelling units, smoke detectors powered by a hard wire AC primary power source or a self-monitored, non-removal ten-year lithium battery shall be installed and maintained ... Single station detectors presently installed utilizing standard batteries may continue to be used as long as the units remain operational. ...{3} Smoke detectors shall be installed in accordance with applicable NFPA Standards and the manufacturer's recommendations. Detectors may be ceiling or wall mounted, provided that they shall be mounted at a minimum of four inches and a maximum of 12 inches from the ceiling {4} In a dwelling unit the detector shall be located in the corridor within the unit or interior area giving access to the rooms used for sleeping purposes. Where sleeping areas are separated and/or where a single smoke detector will not adequately service all sleeping areas, there shall be a smoke detector installed adjacent to each sleeping area... {C1} The owner of a dwelling shall be responsible for supplying and installing ... detectors ... {C2} The owner of a dwelling shall be responsible for maintenance and testing of detectors, in accordance with the manufacturer's instructions which are located in common areas...{C4} At every change of tenancy in all multi-family residential units and dormitories, it shall be the duty of the owner to test and ascertain that those detectors contained in the unit are in operable condition, and if not, the owner shall be responsible for placing them in operable condition. {C6} It shall be the responsibility of the property owner to install at least smoke detectors powered by a hardwire AC primary source or a self-monitored, non-removal ten year lithium battery before transfer of the property to a new party... · Violation · ENF-PMNT-25-014454
- X07 - DOOR (EXTERIOR) [156.053-O-1, 156.053-O-2] All exterior doors, door assemblies and hardware shall be maintained in good condition? [156.053-O-2] (Door lock provision for principle entry) Double cylinder dead bolts requiring a key operation on both sides are prohibited on required means of egress. · Violation · ENF-PMNT-25-014454
- E02 - ELECT. LIGHTING FIXTURE [156.184-C] Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain at least one electric lighting fixture. · Violation · ENF-PMNT-25-014454
- E03 - ELECT. RECEPTACLE OUTLET(S) [156.184-B] Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or receptacle with a ground fault circuit interrupter. Every bathroom shall contain at lest one receptacle. Any new or replaced bathroom receptacle outlet shall have ground fault circuit interrupter protection. · Violation · ENF-PMNT-25-014454
- I11 - FLOOR (INTERIOR) [156.054-C] All interior surfaces...shall be maintained in good, clean and sanitary condition. ...Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. · Violation · ENF-PMNT-25-014454
- K10 - KITCHEN SINK [156.151-A] Every dwelling unit shall contain its own ... kitchen sink which shall be maintained in a sanitary, safe working condition. ... · Violation · ENF-PMNT-25-014454
- M99 - AIR CONDITIONING UNITS [156.051-B-7] Supplied Fixtures and Equipment: The owner or occupant of a structure or part thereof shall keep all equipment and fixtures therein clean and sanitary, and shall be responsible for the exercise of reasonable care in their proper use and operation. The owner shall maintain the supplied equipment and fixtures in good and proper operating condition. All air conditioning units must be maintained in a safe and operable condition. · Violation · ENF-PMNT-25-014454
- T05 - BATHTUB/SHOWER [156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D] {A} Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. ... {B} At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. {C} Where private water closets, lavatories, and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each ten occupants... [156.155-A] Every...plumbing facility shall be properly connected to either the public sewer system or to an approved private sewage disposal system which shall meet the requirements of the Louisville/Jefferson County Department of Health... [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed... [156.054-C-2] ...The walls of every bathroom, to a height of 48 inches if there is a tub and 72 inches if there is a shower, shall be constructed of water-repellent material in that area adjacent to the tub or shower to prevent structural deterioration and any development of unsanitary conditions... [156.154-C] The water supply system shall ... provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks... {D] Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 120? F (49?C). · Violation · ENF-PMNT-25-014454
- T22 - LAVATORY BASIN [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. All plumbing fixtures shall be maintained in a safe, sanitary and functional condition. · Violation · ENF-PMNT-25-014454
- I13 - INTERIOR SURFACE(S)/ CEILINGS/ WALLS/ FLOORS [156.054-C/156.054-C-1] {C} All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking, or abraded paint shall be repaired, removed, or covered. Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. {C-1} The owner must comply with federal and state statues and standards and local statutes and standards for the abatement of existing lead base paint and the application of lead base paint. · Violation · ENF-PMNT-25-014454
- X07 - DOOR (EXTERIOR) [156.053-O-1, 156.053-O-2] All exterior doors, door assemblies and hardware shall be maintained in good condition? [156.053-O-2] (Door lock provision for principle entry) Double cylinder dead bolts requiring a key operation on both sides are prohibited on required means of egress. · Violation · ENF-PMNT-25-014454
- 02A - CLEANING [156.052-D/156.055-A/156.052-K] {156.052-D}.....All premises shall be maintained free from weeds or plant growth in excess of ten inches. All noxious weeds shall be prohibited. Any land of more than three acres that abut another parcel which contains a dwelling or commercial building thereon shall be weed free at least 50 feet from the property line or 200 feet from an occupied structure, or {156.055-A} All exterior property and premises, and the interior of every structure, shall be free from any accumulation of rubbish or garbage, or {156.52-I} No person shall willfully or wantonly damage, mutilate or deface any exterior surface by placing thereon any marking, carving or graffiti. It shall be the responsibility of the owner to restore said surface. · Violation · ENF-PMNT-25-014454
- E02 - ELECT. LIGHTING FIXTURE [156.184-C] Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain at least one electric lighting fixture. · Violation · ENF-PMNT-25-014454
- E03 - ELECT. RECEPTACLE OUTLET(S) [156.184-B] Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or receptacle with a ground fault circuit interrupter. Every bathroom shall contain at lest one receptacle. Any new or replaced bathroom receptacle outlet shall have ground fault circuit interrupter protection. · Violation · ENF-PMNT-25-014454
- I11 - FLOOR (INTERIOR) [156.054-C] All interior surfaces...shall be maintained in good, clean and sanitary condition. ...Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. · Violation · ENF-PMNT-25-014454
- K10 - KITCHEN SINK [156.151-A] Every dwelling unit shall contain its own ... kitchen sink which shall be maintained in a sanitary, safe working condition. ... · Violation · ENF-PMNT-25-014454
- M99 - AIR CONDITIONING UNITS [156.051-B-7] Supplied Fixtures and Equipment: The owner or occupant of a structure or part thereof shall keep all equipment and fixtures therein clean and sanitary, and shall be responsible for the exercise of reasonable care in their proper use and operation. The owner shall maintain the supplied equipment and fixtures in good and proper operating condition. All air conditioning units must be maintained in a safe and operable condition. · Violation · ENF-PMNT-25-014454
- T05 - BATHTUB/SHOWER [156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D] {A} Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. ... {B} At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. {C} Where private water closets, lavatories, and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each ten occupants... [156.155-A] Every...plumbing facility shall be properly connected to either the public sewer system or to an approved private sewage disposal system which shall meet the requirements of the Louisville/Jefferson County Department of Health... [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed... [156.054-C-2] ...The walls of every bathroom, to a height of 48 inches if there is a tub and 72 inches if there is a shower, shall be constructed of water-repellent material in that area adjacent to the tub or shower to prevent structural deterioration and any development of unsanitary conditions... [156.154-C] The water supply system shall ... provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks... {D] Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 120? F (49?C). · Violation · ENF-PMNT-25-014454
- T22 - LAVATORY BASIN [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. All plumbing fixtures shall be maintained in a safe, sanitary and functional condition. · Violation · ENF-PMNT-25-014454
- I13 - INTERIOR SURFACE(S)/ CEILINGS/ WALLS/ FLOORS [156.054-C/156.054-C-1] {C} All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking, or abraded paint shall be repaired, removed, or covered. Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. {C-1} The owner must comply with federal and state statues and standards and local statutes and standards for the abatement of existing lead base paint and the application of lead base paint. · Violation · ENF-PMNT-25-014454
- X07 - DOOR (EXTERIOR) [156.053-O-1, 156.053-O-2] All exterior doors, door assemblies and hardware shall be maintained in good condition? [156.053-O-2] (Door lock provision for principle entry) Double cylinder dead bolts requiring a key operation on both sides are prohibited on required means of egress. · Violation · ENF-PMNT-25-014454
- Lien notification — Final By Citation · Lien · ENF-PMNT-25-014454
- 02A - CLEANING [156.052-D/156.055-A/156.052-K] {156.052-D}.....All premises shall be maintained free from weeds or plant growth in excess of ten inches. All noxious weeds shall be prohibited. Any land of more than three acres that abut another parcel which contains a dwelling or commercial building thereon shall be weed free at least 50 feet from the property line or 200 feet from an occupied structure, or {156.055-A} All exterior property and premises, and the interior of every structure, shall be free from any accumulation of rubbish or garbage, or {156.52-I} No person shall willfully or wantonly damage, mutilate or deface any exterior surface by placing thereon any marking, carving or graffiti. It shall be the responsibility of the owner to restore said surface. · Violation · ENF-PMNT-25-014454
- E02 - ELECT. LIGHTING FIXTURE [156.184-C] Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain at least one electric lighting fixture. · Violation · ENF-PMNT-25-014454
- E03 - ELECT. RECEPTACLE OUTLET(S) [156.184-B] Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or receptacle with a ground fault circuit interrupter. Every bathroom shall contain at lest one receptacle. Any new or replaced bathroom receptacle outlet shall have ground fault circuit interrupter protection. · Violation · ENF-PMNT-25-014454
- I11 - FLOOR (INTERIOR) [156.054-C] All interior surfaces...shall be maintained in good, clean and sanitary condition. ...Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. · Violation · ENF-PMNT-25-014454
- K10 - KITCHEN SINK [156.151-A] Every dwelling unit shall contain its own ... kitchen sink which shall be maintained in a sanitary, safe working condition. ... · Violation · ENF-PMNT-25-014454
- M99 - AIR CONDITIONING UNITS [156.051-B-7] Supplied Fixtures and Equipment: The owner or occupant of a structure or part thereof shall keep all equipment and fixtures therein clean and sanitary, and shall be responsible for the exercise of reasonable care in their proper use and operation. The owner shall maintain the supplied equipment and fixtures in good and proper operating condition. All air conditioning units must be maintained in a safe and operable condition. · Violation · ENF-PMNT-25-014454
- T05 - BATHTUB/SHOWER [156.151-A,B,C -156.155-A - 156.153-A - 156.054-C-2 - 156.154-C, D] {A} Every dwelling unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a sanitary, safe working condition. ... {B} At least one water closet, lavatory and bathtub or shower shall be supplied for each four rooming units. {C} Where private water closets, lavatories, and baths are not provided, one water closet, one lavatory and one bathtub or shower having access from a public hallway shall be provided for each ten occupants... [156.155-A] Every...plumbing facility shall be properly connected to either the public sewer system or to an approved private sewage disposal system which shall meet the requirements of the Louisville/Jefferson County Department of Health... [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed... [156.054-C-2] ...The walls of every bathroom, to a height of 48 inches if there is a tub and 72 inches if there is a shower, shall be constructed of water-repellent material in that area adjacent to the tub or shower to prevent structural deterioration and any development of unsanitary conditions... [156.154-C] The water supply system shall ... provide a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks... {D] Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a temperature of not less than 120? F (49?C). · Violation · ENF-PMNT-25-014454
- T22 - LAVATORY BASIN [156.153-A] All plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. All plumbing fixtures shall be maintained in a safe, sanitary and functional condition. · Violation · ENF-PMNT-25-014454
- I13 - INTERIOR SURFACE(S)/ CEILINGS/ WALLS/ FLOORS [156.054-C/156.054-C-1] {C} All interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking, or abraded paint shall be repaired, removed, or covered. Cracked or loose plaster, decayed wood, and other defective surface conditions shall be corrected. {C-1} The owner must comply with federal and state statues and standards and local statutes and standards for the abatement of existing lead base paint and the application of lead base paint. · Violation · ENF-PMNT-25-014454
- X07 - DOOR (EXTERIOR) [156.053-O-1, 156.053-O-2] All exterior doors, door assemblies and hardware shall be maintained in good condition? [156.053-O-2] (Door lock provision for principle entry) Double cylinder dead bolts requiring a key operation on both sides are prohibited on required means of egress. · Violation · ENF-PMNT-25-014454